Standard Data | Dimension(mm) | 38×30×16.five | |
Bodyweight ( g ) | ≈33g | ||
Contact Arrangement | 1A/1B | ||
Get in touch with Substance | AgSnOtwo | ||
Ambient Temperature | -forty~+70ºC | ||
Ambient Humidity | 45%~ninety%RH | ||
Vibration | ten~55Hz,1.5mm(DA) | ||
Specification Knowledge | Nominal Voltage | six~48VDC | |
Power Use | One Coil:1.5W, Twin Coil:3W | ||
Max. Switching Voltage | 250VAC | ||
Max. Switching Current | 60A | ||
Max. Switching Power | 15000 VA | ||
Speak to Resistance | <1.5 mΩ | ||
Insulation Resistance | 1000MΩ(DC 500V) | ||
Dielectric Creepage | 10mm | ||
Dielectric Strength | Throughout Open Contact | >1500VAC 1min | |
Coil to Contact | >4000VAC 1min | ||
CZPTal Existence | >10,000cycles | ||
Mechanical Life | >100,000cycles | ||
Selecting-up & Launch Time | <=20ms | ||
Pulse Duration | >=100ms | ||
Functional Shock Resistance | 10G | ||
Harmful Shock Resistance | 100G |
Cautions of Latching Relay:
1.Ideas of relay’s input
(one)Polarity-Please check out the polarity inside of of our technological specification, if one coil then”+ -” or “- +”are wonderful,
you can change it by 1 pulse.If double coil then it’s essential to verify “-+-” or “+-+”just before leaving the our manufacturing unit.
(2)Driving-Remember to energize the relay at our advocate pulse width, rated voltage for reputable overall performance, if one.five
moments or 2 times of price or lower driving condition plz validate with our engineer.
(three)Relays’contact standing may possibly be transformed throughout transportation or set up thanks to impact of exterior power,
consequently make sure you reset to the needed status.
two.Ideas of relay’s output
(one)When picking the relay with difficult link,remember to steer clear of the external force on load terminals for the duration of or following
the installation.
(2)When the relay will be related with screw or bolts to the relays’ terminals, plz make confident your connection is
fixed and prevent relay from damages or other protection problems due to temp. Rise..
(3)The sampling signal wires of merchandise are minimal, you should do not pull or torque throughout set up.